MP-40 PDF with DAkkS certificate

Measurement microphone " IEPE  Type MP-40 including DAkkS calibration

certificate | Price: RFQ


MP-40 " IEPE microphone  comply WS2F DIN IEC 61094-4 | Price: RFQ


model

measurement microphone

euro

 

MI-21

MI-21; 1/4" IEPE measurement microphone, 50 mV / Pa, constant current supply 2-8 mA BNC connection, including WS-RG-50 windscreen. Splash-Proof

Frequency response 5 Hz-20 kHz, free field, corresponds to class 1 including individual Calibration sheet (sensitivity & frequency response)

Self-noise 26 dB (A)

Download MI-21 PDF

 

RFQ

 

MR10

MR10; 1/4"Weatherproof IEPE measuring outdoor microphone,

50 mV/Pa, constant current supply 2-8 mA TNC connection, including rain protection.

Frequency response 20 Hz-20 kHz, equivalent to class 1.5 including individual

Calibration sheet (sensitivity & frequency response) floor noise 26 dB (A).

Download MR-10 PDF

 

RFQ

 

RG-20-PC

RG-20-PC; 1/4"measuring microphone, voltage-powered 4-15 volts, using the microphone PC input, frequency response 5 Hz - 20 kHz, corresponds to class 1. Including free spectrum analyzer software.

Download RG-20-PC PDF

 

 

RFQ

 

MP-40

MP-40; 1/2 "measuring electret microphone, WS2F (DIN IEC 61094-4),

Frequency range 5Hz - 20kHz

free field

Including preamplifier PA-01

Dynamic range 16dB (A) -146dB

Constant power fed

Sensitivity: 40 mV / Pa

Download MP-40 PDF

 

RFQ

 

CA111

Sound calibrator; Conforms to IEC 60942 Class 1 for 1/2 "& 1/4" microphone capsules with quartz-controlled oscillator to verify accuracy on IEC 60942 Class 1 sound level meters.

94 dB and 114 dB @ 1000 Hz output level selectable

Download CA1xx PDF

 

RFQ

 

CA114

Sound pressure calibrator; Conforms to IEC 60942 Class 2 for 1/2 " & 1/4" microphone capsules with quartz-controlled oscillator to verify accuracy on IEC 60942 Class 2 sound level meters. 94 dB @ 1000 Hz output level

Download CA1xx PDF

RFQ

MI-MH

Microphone holder for MP40 1/2 "measuring microphone

 

42

WS-RG-30

MI-21, MI-17, measuring microphone wind screen; 30 mm diameter

 

 29

WS-RG-40

MI-21, MI-17, measuring microphone wind screen; 40 mm diameter

 

 29

WS-RG-50

MP-40, MI-21, MI-17, microphone wind screen; 50 mm diameter

 

 32

WS-RG-80

MP-40,  measuring microphone wind screen 80 mm diameter

 

 32

AS-11

AS-11; Directional Microphone Frequency selective band for airborne noise and sound source localization | single hand operating Tunable with -octave bandwidth, 31 Hz - 8 kHz and additional amplification of 20 dB Incl. headphone, charger, windscreen, analog output cable and case. Weight: 4 kg

Download AS-11 PDF

 

RFQ

Impedance Tube Price

Sound Absorption Coefficient (α) and Transmission Loss (TL)

Sound Absorption Standard: GB/T-18696, 2-2002, ISO10534-2, 1998; ASTM E1050-08 ASTM E2611-09

SW422

+ SW477

For accurate measurement of sound absorption coefficients (63-6300Hz) and transmission loss(60-6300Hz), includes:

- a 100mm diameter tube

- a 100mm diameter sample holder

- a 100mm diameter extension tube

- a 30mm diameter tube

- a 30mm diameter sample holder

- a 30mm diameter extension tube

Including

PA50; Power Amplifier of 50W

MC3242; DAQ card with 4 ICP input channels and 2 signal output channels, USB power supply, 0-20kHz, connected with laptop.

4* MPA416; 1/4" microphone with ICP Preamp

CA115; 1000Hz, 114dB sound calibrator, Type 2, with adaptor for 1/2'' and 1/4'' microphones

VA-Lab4 BASIC; Base software for measurement of noise and vibration, used for 4 channels

VA-Lab4 IMP-A; Software for measurement of material impedance values (4 mics are needed), for measurement of Transfer Function and the calculation of sound impedance coefficients and sound impedance.

Download Impedance Tube Solutions PDF

 

 

RFQ